Downloaded from https://www.everyspec.com MIL-STD-1311D GRID CURRENT METHOD 3216 (Thyratron) 1. With the tube operating under the specified conditions, for which the anode supply shall be a reversing voltage, the grid bias shall be increased in a negative direction to a value, Ecco (1), at which the tube just cuts off. The negative grid bias shall then be made zero, and the specified grid resistance shall be reduced to 10,000 ohms, and the anode current readjusted to the value specified. The grid bias shall again be increased in a negative direction to cutoff, Ecco (2). The grid current shall be computed from the following formula: 2.
The grid current as determined in accordance with 1 above, shall not exceed the maximum limit specified. ) ( ) ( ) 2 ( )1( ) ( Meg in Rg volts in Ecco Ecco dc A in Ic = µ METHOD 3216 3216-1 19 April 1968