Downloaded from https://www.everyspec.com MIL-STD-1311D HIGH FREQUENCY OPERATION METHOD 3214 (Thyratron) 1. Purpose. The purpose of this test is to determine: a. Whether the tube would have full grid control up to the specified minimum frequency (maximum deionization time) rating. b. Whether the tube has the proper gas pressure as evidenced by the maximum cutoff frequency. 2. Equipment. The basic test circuit shown on figure 3214-1 shall be used. The circuit parameters shall be as specified on the individual TSS. FIGURE 3214-1. High-frequency operation. 3. Procedure.
The frequency of the anode voltage supply (Epp) shall be set well above the maximum limit specified on the TSS with the specified positive bias on the tube. Switch (S) is in position 1. a. The value of the anode voltage supply and series anode resistor shall then be adjusted for the specified operating conditions while the tube is conducting. b. Switch the position 2 and reduce the frequency of the anode supply voltage until the tube cuts off. 4. Acceptance criteria. The frequency at the cutoff point shall be within the limit(s) specified on the TSS. METHOD 3214 3214-1 19 April 1968