Downloaded from https://www.everyspec.com MIL-STD-1311D INSTANTANEOUS STARTING METHOD 3267A (Hydrogen pulse modulators) NOTE: This test shall be the first high-voltage test to be conducted after the specified holding period. 1. No voltages shall be applied prior to the start of this test. Filament and reservoir voltages shall be applied for the specified warm-up time, and grid drive voltage shall be applied not more than 10 seconds in advance of the application of anode voltage. The filter in the anode power supply shall be such that epy rises from zero to the specified value within .03 seconds. Intervals between successive attempts shall be not less than 10 seconds nor more than 30 seconds.

2. The tube shall operate satisfactorily with the anode voltage applied. Any tube failing to start or continue to operate for at least 10 seconds within the maximum number of trials specified shall be considered a failure. 3. The circuit indicated in figure 3246-1 shall be used when conducting this test. METHOD 3267A 3267-1 25 March 1970