Department of Defense MIL-STD-1311D — MIL-STD-1311D Test Methods for Electron Tubes — DoD Standard Manual PDF

Downloaded from https://www.everyspec.com MIL-STD-1311D MODULATOR TEST, DUAL CONTROL GRID TETRODE THYRATRONS Dual control grid tetrodes. Dual control grid tetrode thyratrons shall be tested in the basic circuit shown on figure 3273-1. The respective grid drive amplitude and phasing shall be as specified on the TSS. METHOD 3273 NOTE: Include R V as part of R . FIGURE 3273-1. Basic modulator circuit for dual control grid switch tubes. METHOD 3273 3273-1 19 April 1968