Downloaded from https://www.everyspec.com MIL-STD-1311D METHOD 3278A NOISE AND OSCILLATION (Cold cathode discharge types) Test equipment. The tube shall be operated from a well-filtered variable dc supply, the output capacitance of which shall be at least 16 µ F. The voltage from the filter output shall be supplied to the tube through a series resistance R1 of 500 ohms. The internal connection between the base pins shall be connected in series with one of the tube electrodes. The test circuit is shown on figure 3278-1. The tube shall be coupled through a series capacitance of 0.1 µ F to the amplifier.
The amplifier shall have an output within ± 5 dB of its 400 Hz response, over the frequency range of 60 to 5,000 Hz, and shall be capable of producing undistorted output when an input signal is 10 times the calibrating rms voltage. A commercial dynamic loudspeaker, with a rating of at least 2.5 watts and of low impedance, shall be matched to the amplifier and properly excited. 1. Oscillation test. The amplifier gain shall be adjusted for 50 mW output when the specified calibrating signal voltage at 400 Hz is applied to the amplifier input.
The current through the tube shall be varied in each direction between the minimum and the maximum specified values, using either voltage or load variation, and taking not less than 2 seconds to traverse the range. No oscillation persisting over a current range of more than 2 mA dc shall be generated as evidenced by aural observations. 2. Noise test. With the conduction current reduced to the value specified, the tube shall be tapped as specified in method 1201 for tap shorts; tapping procedure for receiving tubes, or the tapping procedure for other than receiving tubes.
The amplifier gain shall be adjusted for 50-mW output when the maximum voltage limit specified is applied at 400 Hz to the amplifier input. Tubes producing a voltage disturbance to the amplifier which exceeds the specified limit shall be rejected. METHOD 3278A 3278-1 25 March 1970