Downloaded from https://www.everyspec.com MIL-STD-1311D VOLTAGE DROP METHOD 3337 (Cold cathode discharge types) Under the specified conditions and with the tube conducting current for at least 0.1 second, the tube voltage drop shall be within the limit(s) specified. METHOD 3337 3337-1 19 April 1968