Downloaded from https://www.everyspec.com MIL-STD-1311D VOLTAGE JUMP METHOD 3345A (Voltage regulator and reference) 1. Purpose. Tube voltage jump is defined as an abrupt change or discontinuity in tube voltage drop when the tube current is varied. 2. Procedure. Voltage regulator and reference tubes shall be tested for voltage jump by cycling the tube current between the specified minimum and maximum values for a minimum of one complete cycle. One complete cycle consists of varying the tube current between the minimum and maximum values in both the current increasing and current decreasing direction.
The total ambient noise level of the supply voltage and test equipment shall be not greater than 20 percent of the maximum allowable voltage jump. The variation of the tube current in any one direction shall be accomplished in not less than 3 seconds, nor more than 30 seconds. The current sweep may be linear, exponential, or sinusoidal. Unless a specific filter is specified, the TUT shall be coupled to the readout device by the filter shown on figure 3345-1. NOTE: Use nonelectrolytic capacitors. FIGURE 3345-1. Test circuit. The filter shall be terminated with a resistance of 1 megohm including the input resistance of the following stage or read-out device.
The read-out device shall be an oscilloscope, or an equivalent device, capable of measuring a voltage change having a 10- microsecond rise time. Unless otherwise specified, tubes shall be operated at the maximum rated test current value for a period of not less than 15 seconds, and the test shall be continued for the specified number of cycles to determine whether the voltage jump is reproducible. NOTE: (a) A voltage jump may not necessarily recur at a constant current value. (b) Switching transients may occur at each end of the sweep and should not be confused with a voltage jump. METHOD 3345A 3345-1 25 March 1970