Department of Defense MIL-STD-1311D — MIL-STD-1311D Test Methods for Electron Tubes — DoD Standard Manual PDF

Downloaded from https://www.everyspec.com MIL-STD-1311D VIBRATION DETUNING METHOD 4016 (Tunable gas-switching tubes) 1. Purpose. To check the stability of the tuning mechanism of a tunable frequency tube under specified vibration conditions. 2. Equipment. The tube shall be vibrated in accordance with method 1031, high-frequency (50 Hz) vibration, using a suitable short circuit indicator (method 1041 or equivalent). 3. Procedure. The tube shall be tuned to resonance at the microwave frequency specified and then vibrated in the direction of the tuner axis. After vibration, the tuning shall not have changed by more than the specified amount, and the tube shall not have been physically damaged.

METHOD 4016 4016-1 19 April 1968