Downloaded from https://www.everyspec.com MIL-STD-1311D DEGRADATION DUE TO VIBRATION METHOD 4021 (Gas-switching tubes) 1. Purpose. The purpose of this test is to determine whether the ignitor electrode will short circuit during the vibration cycle, whether the tube will detune, and whether the tube will remain vacuum tight after the vibration cycle. 2. Equipment. The tube shall be vibrated in accordance with method 1031, high-frequency (50 Hz) vibration, using a suitable short circuit indicator (method 1041 or equivalent). 3. Procedures. a. TR tubes shall be vibrated in a plane perpendicular to the ignitor axis under the conditions specified.
During this interval there shall be no evidence of shorting between the ignitor electrode and the adjacent cone. After this test, the tube shall satisfy the VSWR (method 4473) and the ignitor voltage drop tests (method 4406). b. ATR tubes shall be vibrated in a plane perpendicular to the tuning diaphragm under the conditions specified. After this test, the tube shall satisfy the tuning susceptance (method 4482) and firing time test (method 4486). c. Pre-TR tubes shall be vibrated in a plane perpendicular to the input plane of the tube under the conditions specified. After this test, the tube shall satisfy the arc loss test (method 4488). METHOD 4021 4021-1 19 April 1968