Downloaded from https://www.everyspec.com MIL-STD-1311D (OBSOLESCENT) METHOD 4026 DEGRADATION DUE TO SHOCK (Gas-switching tubes) 1. Purpose. The purpose of this test is to determine whether the ignitor electrode will short circuit during the shock test, whether the tube has been detuned by the shock, and whether the tube remained vacuum tight after the shock. 2. Equipment. Suitable shock machine capable of meeting the conditions specified with a short-circuit indicator and fixture. 3. Procedure. 3.1 Method of mounting. The tube shall be mounted to a fixture that utilizes all the tube mounting flanges. 3.2 Shock.

The tube shall be subjected to the specified number of shocks of 50 G acceleration and 11 ± 1 millisecond duration in each of the three mutually perpendicular planes. In the case of tubes containing ignitor electrodes, there shall be no evidence of shorts during this test. 4. Acceptance criteria. After procedure 3.2, TR tubes shall satisfy the VSWR (method 4473) and ignitor voltage drop tests (method 4406), ATR tubes shall satisfy the tuning susceptance (method 4482) and firing time tests (method 4486) and, pre-TR tubes shall satisfy the arc loss test (method 4488). METHOD 4026 4026-1 19 April 1968