Downloaded from https://www.everyspec.com MIL-STD-1311D METHOD 4029 MAXIMUM TEMPERATURE COEFFICIENT OF FREQUENCY 1. Purpose. The purpose of this test is to determine the maximum value of the temperature coefficient ( F/ ° C) of the tube over a given temperature range. 2. Equipment. If ambient environmental temperature is to be varied, a chamber shall be used for this test that shall be capable of maintaining the specified temperature. If actual tube temperature is to be varied, a chamber may be used for this test that is capable of maintaining the specified temperature, or alternate methods may be used such as changes in either temperature or flow rate of the cooling air or cooling liquid.
These alternate methods shall be capable of maintaining the specified temperatures. 3. Procedure. The temperature may be that of a specified element or a specified point on the tube surface on which frequency depends. The temperature alternate may be specified as ambient environment. If ambient temperature is the variable, the rate of change of ambient shall not be greater than 2 ° C per minute. 3.1 The test shall start with the tube operating and stabilized at normal room temperature operating conditions. This shall be the starting temperature. The temperature and frequency shall be recorded.
The temperature shall then be raised to a value 30 ° C above the starting temperature and frequency recorded at intermediate values and end point of temperature. The temperature shall then be returned to the starting temperature and frequency recorded at intermediate values and end point of temperature. Measurements of temperature and frequency shall be made after conditions of thermal equilibrium have been reached. 3.2 A smooth curve of frequency versus temperature shall be drawn through the data points. The temperature coefficient ( F/ ° C) shall be the greatest slope of this curve. METHOD 4029 4029-1 19 April 1968