Downloaded from https://www.everyspec.com MIL-STD-1311D THERMAL FREQUENCY DRIFT 1. Purpose. The purpose of this test is to determine the extremes of operating frequency which result from operation of the tube under a variety of ambient conditions, and when there is a severe requirement for frequency stability. 2. Equipment. The test chamber shall be capable of the independent maintenance of the specified ambient temperature and the temperature of the input cooling fluid. Facilities shall be available to operate the tube. 3. Procedure.
The thermal frequency of drift specified shall not be exceeded for any combination of anode inlet cooling temperature and ambient temperature between the values specified. The frequency difference between the maximum and minimum frequencies observed as F1 through F5 shall not exceed the value specified. The conditions are as follows. 3.1 With chamber temperature and anode inlet coolant temperature at 30 ° C ± 10 ° C, the stated conditions for operation shall be applied, and the frequency is measured and noted as F1 after stability has been reached.
The tube is stabilized when the frequency difference between the maximum and minimum frequency measured over a period of 1 hour at 5-minute intervals shall not exceed 0.05 percent of the operating frequency. 3.2 Adjust chamber temperature to the stated upper limit and the anode inlet coolant temperature to its stated upper limit. After the frequency has stabilized, measure the frequency and note as F2. 3.3 Repeat 3.2 except maintain tube chamber temperature at the upper limit and adjust anode inlet coolant temperature to the lower limit and note stabilized frequency as F3.
3.4 Repeat 3.2 except adjust chamber temperature to the lower limit and the anode inlet coolant temperature to its lower limit and note the stabilized frequency as F4. 3.5 Repeat 3.2 except maintain chamber temperature at the lower limit and adjust anode inlet coolant temperature to the upper limit and note stabilized frequency as F5. 3.6 If an unintentional interruption of the test occurs in the first 10 minutes of the test, discontinue further testing and start over. If an unintentional interruption occurs after the first 10 minutes of the test, it is permissible to normalize the data and continue the test. METHOD 4030 METHOD 4030 4030-1 19 April 1968