Downloaded from https://www.everyspec.com MIL-STD-1311D LIQUID COOLING JACKET LEAKAGE 1. Purpose. To establish the integrity of the liquid-cooling system so that high-voltage insulation will not deteriorate due to the presence of cooling liquid as well as to eliminate any need to dispose of leaked liquid. 2. Equipment. A source of air or nitrogen at the required pressure and a supply of liquid soap or detergent for leak checking. 3. Procedure. The cooling system shall be emptied and dried. The liquid cooling connections shall be completed, without coolant, and the pressure system and the tube shall be coated with liquid soap or detergent.
Gas at the required pressure shall be applied to the liquid cooling jacket for 1 minute minimum. Leaks are indicated by the formation of bubbles in the liquid soap. METHOD 4153 METHOD 4153 4153-1 19 April 1968