Downloaded from https://www.everyspec.com MIL-STD-1311D CATHODE EMISSION 1. Purpose. The purpose of this measurement is to determine the degree of cathode activity measured under controlled conditions. 2. Procedure. The cathode current shall be measured with the tube operating as specified. The filament or heater voltage shall be changed to the lower value specified. The cathode current shall be remeasured after the specified time. If the TSS does not specify a time, the stabilized cathode current shall be measured. The change in cathode current shall be divided by the initial value and expressed as a percentage. 3. Precaution.