Downloaded from https://www.everyspec.com MIL-STD-1311D REFLECTOR VOLTAGE MODULATOR COEFFICIENT METHOD 4215 (Reflex klystrons) 1. Purpose. To determine the frequency change caused by variations in reflector voltage. 2. Definition. The reflector voltage modulation coefficient is the ratio of (1) the change in output frequency, caused by (2) an incremental change in reflector voltage. 3. Equipment. 3.1 Power supplies to provide normal operating voltage and currents. 3.2 A means of observing and measuring the changes in output frequency caused by changes in the applied reflector voltage. 3.3 A means for varying and measuring the changes in reflector voltage. 4. Procedure.
4.1 Method A (dynamic). 4.1.1 The tube shall be operating under test conditions as specified in the TSS. 4.1.2 The reflector voltage shall be adjusted to the maximum output power point, or any other measurement point(s) specified in the TSS. 4.1.3 Raise and lower the reflector voltage a known amount by superimposing on the dc reflector voltage a 60 Hz voltage of the specified value (usually a few volts peak-to-peak) and record the lowest and highest output frequencies generated by the tube. 4.1.4 The reflector voltage modulation coefficient is the difference in output frequencies, recorded in 4.1.3 divided by the absolute change in reflector voltage and shall be within the limit specified.
4.2 Method B (static). 4.2.1 The tube shall be operating under test conditions as specified in the TSS. 4.2.2 The reflector voltage shall be adjusted to the maximum output power point, or any other measurement point(s) specified in the TSS. 4.2.3 The reflector voltage shall be reduced a small known amount (usually a few volts) and after 60 seconds, record the reflector voltage and output frequency. 4.2.4 The reflector voltage shall be increased a similar known amount above the initial value, and after 60 seconds, record the reflector voltage and output frequency.
4.2.5 The reflector voltage modulation coefficient is the difference in output frequency, recorded in 4.2.3 and 4.2.4, divided by the difference in reflector voltage, recorded in 4.2.3 and 4.2.4 and shall be within the limit(s) specified. 5. Precautions. The reflector voltage modulation coefficient reaches a minimum near the maximum output power point of the reflector voltage mode, and increases rapidly on both sides of this minimum point. Theoretically, the modulation coefficient data should be taken with an infinitely small value of modulation voltage, sweeping equally on either side of the specified measurement point.
In practice, the smallest modulation voltage that will give reliable data should be used. METHOD 4215 4215-1 13 September 1972