Downloaded from https://www.everyspec.com MIL-STD-1311D FIGURE 4243-1. Spurious output ratio setup. 4. Procedure. The tube shall be tested for spurious output power using either method below. 4.1 Method A (Spectrum analyzer method). With the tube operating under the specified conditions, the frequency is manually or dynamically swept over the specified band. The dispersion of the spectrum analyzer should be set to encompass this band of frequencies. Using the precision attenuator, the ratio of (1) the peak of the power output indication to (2) the peak indication of the simultaneously existing spurious signal output shall be measured directly in dB and shall exceed the specified value.
4.2 Method B (Oscilloscope method). With the tube operating at one end of the band under the specified conditions the tunable filter is swept manually or dynamically throughout the required frequency region. If signals other than the main output signal are indicated, retune the filter to the power output signal and adjust the precision attenuator to the reference level for that frequency on the oscilloscope. The filter is then manually tuned to the spurious output signal, its frequency is measured and the attenuator is readjusted to the reference level which corresponds to that frequency .
The difference between the attenutor reading now obtained and the earlier value expressed in dB is the required measurement and must be greater than the specified value. This process is repeated at as many frequencies throughout the required band as is required to demonstrate that proper performance is everywhere observed. Sometimes the tracking of the spurious signal while tuning the tube will permit a single measurement at the conditions for maximum spurious output, thus simplifying the procedure. NOTE: The frequency range on either side of the main power component may be excluded from this test, as shown on the TSS. METHOD 4243A 4243-2 25 March 1970