Department of Defense MIL-STD-1311D — MIL-STD-1311D Test Methods for Electron Tubes — DoD Standard Manual PDF

Downloaded from https://www.everyspec.com MIL-STD-1311D SPURIOUS OUTPUT RATIO 1. Purpose. To determine the amplitudes of spurious output signals. 2. Definitions. Spurious output signals are undesired outputs having a degree of coherence sufficient to distinguish them from white noise. Harmonics of the fundamental desired signal are normally considered separately. The spurious output ratio is the value of the ratio expressed in dB between (1) the fundamental frequency output power and (2) the largest co-existing spurious output signal within the band specified for spurious search. 3. Equipment. 3.1 Equipment to operate the tube as on figure 4243-1.

3.2 Means for changing the frequency of the tube or tunable filter, manually or dynamically, over the specified portion of the tuning range. 3.3 Means for measuring spurious output: Either of a. Spectrum Analyzer with the following characteristics: (1) Tunable frequency range as required. (2) Display bandwidth as needed to simultaneously display both power output and spurious signal outputs. (3) Sweep speeds which are so low compared to the dynamic tuning rate (see precautions) used in the measurement that the indicator shall produce a true response to all spectral components present.

(4) Dynamic range of the indicator system shall exceed the range encompassing power output and spurious output power. b. Oscilloscope, tunable filter and microwave detector: (1) The rise time of the oscilloscope, the rate of tuning of the filter, and the Q of the wavemeter should be mutually compatible so that all spurious responses are fully indicated. (2) It is often convenient to mark the face of the oscilloscope with the locus of one or more levels of calorimetrically measured power versus frequency, as a means of calibrating sensitivity versus frequency. NOTE: The frequency calibration which is derived from the tuning voltage is only correct for the main output signal.

System sensitivity to other modes whose frequency is measured by the tunable filter can be determined by the locus value at the corresponding horizontal deflection calibration. METHOD 4243A METHOD 4243A 4243-1 25 March 1970