Department of Defense MIL-STD-1311D — MIL-STD-1311D Test Methods for Electron Tubes — DoD Standard Manual PDF

Downloaded from https://www.everyspec.com MIL-STD-1311D METHOD 4253 GAIN (Microwave amplifier tubes) 1. Purpose. To determine the power gain of a microwave amplifier tube. 2. Test methods. The TSS shall specify whether the gain is to be measured under small signal, saturated, or other conditions. 2.1 Method A (directional coupler method). 2.1.1 Test circuit. FIGURE 4253-1. Directional coupler method. 2.1.2 Test circuit. FIGURE 4253-2 Attenuator method 2.1.3 Procedure. With the TUT inserted in the circuit shown on figure 4253-1 (or 4253-2) the input power to the TUT and the output power from the TUT are measured.

The gain of the TUT in dB is the output power in dBm minus the input power in dBm. 2.1.4 Precautions. 2.1.4.1 Appropriate filters will be used if required by TSS for measurement of power output. 2.1.4.2 In the case of high-gain broadband amplifiers, the broadband noise power output of the TUT may be of sufficient magnitude to affect significantly the results obtained with these methods. Spurious output signals can also be of significant magnitude. Simple subtraction of the noise or spurious contributions can give an incorrect answer. In these cases band limiting filters should be used ahead of power indicating devices. METHOD 4253 4253-1 19 April 1968