Downloaded from https://www.everyspec.com MIL-STD-1311D 4.1.2 Procedure. The measuring circuit (see figure 4256-1) shall consist of a reference directional coupler and a measuring directional coupler connected to a device which indicates the ratio of the reflector signal power to the incident signal power. Directional couplers shall be chosen such that at the power level used square law operation of the detectors is assured. Calibration shall be accomplished by means of a short circuit or a standard mismatch replacing the TUT. The unmeasured rf connector shall be terminated in a resistive impedance which matches the nominal impedance of the tube as specified on the TSS. 4.1.3 Precautions.
4.1.3.1 This method usually required a square-wave modulated source for use with a ratiometer. When measuring hot match on a pulse tube, certain errors may result when using the conventional ratiometer technique. 4.1.3.2 The signal source shall be sufficiently decoupled from its load. 4.1.3.3 Hot input and output matches may depend upon signal level because of tube non-linearity. 5. Method 2A (comparison to a calibrated mismatch). 5.1 Test circuit. FIGURE 4256-2. Comparison to calibrated mismatch. 5.2 Procedure. With the calibrated mismatch substituted for the TUT, and with a fixed output from the signal source, a baseline and a calibration line are established on the CRO or on the recorder.
Several values of calibrated mismatch may be used if necessary. A calibrated mismatch may be fabricated by using a calibrated attenuator in series with a short circuit. The VSWR is related to the setting of the calibrated attenuator (including line loss) by the following formula (if the measurement to be taken is a power measurement): 1 1 log 10 + = VSWR VSWR dB in setting Attenuator Replace the calibrated mismatch with the TUT and display or record the reflected power from the TUT. The VSWR may be read directly from the display or recording. METHOD 4256 4256-2 19 April 1968