Downloaded from https://www.everyspec.com MIL-STD-1311D AMPLIFIER INSERTION LOSS METHOD 4257 (Microwave amplifier tubes) 1. Purpose. This test is designed to determine the loss a microwave amplifier tube introduces when inserted into a circuit. 2. Definitions. 2.1 Cold-insertion loss (backward and forward). This is performed with no voltages applied to the tube. 2.2 Hot-insertion loss (forward). This is performed with the tube operating, except that the control electrode or anode is set at the specified voltage condition for cutoff. 2.3 Hot-insertion loss (backward). This test is performed with normal operating voltages applied. The signal source is connected to the output of the tube. 3.
Introduction. Cold and hot loss shall be measured by substitution method as shown on figure 4257-1 at the frequencies specified in the test conditions using a suitably isolated signal source and a detector at the input and the output of the tube, respectively. Any one, or combination, of the attenuators shown in the diagram may be used. 4. Test circuit. FIGURE 4257-1. Substitution method. 5. Procedure. With the switch in position 1, set the signal output such that there is a convenient level displayed on the indicator. Note the value of the attenuators. With the switch in position 2, the calibrated attenuators are adjusted to reproduce the same level on the indicator.
Note the value of the attenuators. The amplifier loss is the difference between the sum of the attenuators in position 1 and the sum of the attenuators in position 2. METHOD 4257 4257-1 19 April 1968