Department of Defense MIL-STD-1311D — MIL-STD-1311D Test Methods for Electron Tubes — DoD Standard Manual PDF

Downloaded from https://www.everyspec.com MIL-STD-1311D RADIO INTERFERENCE SHIELDING METHOD 4258 (Microwave tubes) 1. Purpose. The purpose of this test is to determine the amount of rf radiation from the TUT and the susceptibility of a TUT to external rf fields. This test will normally be conducted in a system in its final configuration and not on a tube alone. 2. Method A (shielding to prevent radiation). 2.1 Test circuit. FIGURE 4258-1. Shielding to prevent radiation. 2.2 Procedure.

With the switch in position 1, operate the tube with an input signal level of the specified value over the specified bandwidth, and with the output terminated into a matched load, the leakage power density at a distance of 1 meter from the tube shall be less than the specified value for all tube orientations. Switch position 2 is used for calibration of the system. 2.3 Precautions. 2.3.1 It is recommended the tube be measured in its specified operating environment, or equivalent, since the presence of surrounding material can affect the rf pattern of the horn. 3. Method B (shielding against rf pickup). METHOD 4258 4258-1 19 April 1968