Downloaded from https://www.everyspec.com MIL-STD-1311D 3.1 Test circuit. FIGURE 4258-2. Shielding against rf pickup. 3.2 Procedure. With the tube immersed in a uniform field of the specified watts per square meter of arbitrary polarization and with the input terminated into a matched load, the signal appearing at the output of the test set shown on figure 4258-2 shall not exceed the value specified. The test shall be performed at the given frequencies or over the specified frequency band. The output of the swept oscillator is amplified and the power supplied to the radiating horn is measured.

By use of the directional coupler and precision variable attenuator, the power supplied to the vertical plates of the oscilloscope can be adjusted for a certain deflection at a calibrated power level when the switch is in position 1. When the switch is in position 2, the output of the tube can be measured as a result of the rf field from the horn. 4. Method C (shielding to prevent feedback). 4.1 Test circuit. FIGURE 4258-3. Shielding to prevent feedback. 4.2 Procedure. Connect the TUT as shown on figure 4258-2 with normal voltages applied. Unless otherwise specified, the position of the horn is 1 meter from the tube. With the switch in position 1, note the relative power output.