Downloaded from https://www.everyspec.com MIL-STD-1311D 4.3. Precautions. 4.3.1 Since noise is used as an indicator from the TUT, a band frequency limiter may be required to exclude signals of no interest. 4.3.2 Changes of power indication are a function of orientation of the horn. Unless otherwise specified, find the orientation which produces the maximum change. METHOD 4258 4258-3 19 April 1968