Downloaded from https://www.everyspec.com MIL-STD-1311D AMPLITUDE MODULATION METHOD 4262A (Traveling-wave tubes) 1. Purpose. The purpose of this test is to measure quantitatively the AM appearing on an rf signal as a result of electrical, mechanical, or accoustical stimuli applied to the TUT. 2. Method A (amplitude modulation). 2.1 Test circuit. FIGURE 4262-1 Amplitude modulation method A. 2.2 Procedure. With the TUT operating with specified voltages and stimuli applied, adjust the attenuator to display the rf on the scope. Observe and note the positions of the maximum and minimum. Adjust the attenuator to measure the dB difference between the maximums and minimums, refer to figure 4262-2.

FIGURE 4262-2. Enlarged scope display. 2 dB anti V V = 20 log 1 This can be expressed in percent by 100 1 2 x V V V V + 1 2 = V V V V 2 1 1 2 + 100 1 x 1 METHOD 4262A 4262-1 28 March 1975