Department of Defense MIL-STD-1311D — MIL-STD-1311D Test Methods for Electron Tubes — DoD Standard Manual PDF

Downloaded from https://www.everyspec.com MIL-STD-1311D If a power detector is used, then = 10 log 2 dB anti P P 1 P P which expressed in percent modulation becomes, 1 2 1 x 100 P P 2 + 1 In cases where the AM, as displayed on the scope, is too small to be conveniently displayed, the scope should be calibrated on a less sensitive range with the attenuator, and the scope's sensitivity should then be increased by a known amount. In cases where the AM is very large, the detector may be operating over a non-linear part of its range. The peak-to-peak readings are correct, but further manipulations of the data can lead to errors unless intermediate calibration points are used. 3.

Method B (amplitude modulation based on two -power measurements. 3.1 Test circuit. 1 FIGURE 4262-3. Amplitude modulation based on two -power measurements. METHOD 4262A ` 4262-2 28 March 1975