Downloaded from https://www.everyspec.com MIL-STD-1311D TURN-OFF CONTROL ELECTRODE VOLTAGE 1. Purpose. To determine the change in control electrode voltage needed to reduce the flow of power from normal to a specified low level. 2. Definition. Turn-off control electrode voltage is the change in control electrode voltage required to reduce the normal power to a specified low level of power or dB above KT F. 3. Equipment. METHOD 4276A FIGURE 4276-1. Equipment layout for control electrode voltage measurements. 4. Procedure.

With the tube operating in the circuit of figure 4276-1 for power output, the peak control electrode voltage (using a measuring circuit of method 4306) required to effect turn-off shall be within the limits specified. METHOD 4276A 4276-1 25 March 1970