Downloaded from https://www.everyspec.com MIL-STD-1311D POWER SPECTRAL CHARACTERISTICS 1. Purpose. The purpose of this test is to measure two characteristics of the rf output spectra from self modulated or externally modulated cross field devices. These two characteristics, with freedom from harmonic content, are (a) the total average power (P) within a specified spectral bandwidth (BW), and (b) the bandwidth (BW) at a specified power density level (pdl). 2. Method A (integrator). 2.1 Equipment. METHOD 4277A FIGURE 4277-1. Equipment layout for power spectral characteristics measurements. 2.2 Procedure.
Using the test circuit shown on figure 4277-1, a relative plot of power versus frequency is obtained on the recorder. A typical plot is shown on figure 4277-2. The horizontal frequency scale is determined by the synchronous drive relation between the calibrated tunable filter and the recorder. The vertical scale Y is arbitrary and is determined by the following calculations: Po At x pdl x X Y ) ( = Where: Y = Vertical scale value (expressed in dimensional units, for example, inches) for specified power density level, pdl. pdl = Specified power density level, W/MHz. X = Horizontal scale calibration (expressed in MHz/dimensional units, for example, MHz/inch).
At = Total area under plot (expressed in dimensional units, for example, inch 2 ) and may be measured by a planimeter or any equivalent integration technique. Po = Total average fundamental power output from the TUT. METHOD 4277A 4277-1 25 March 1970