Department of Defense MIL-STD-1311D — MIL-STD-1311D Test Methods for Electron Tubes — DoD Standard Manual PDF

Downloaded from https://www.everyspec.com MIL-STD-1311D 3.3 Procedure. The equipment is set up as on figure 4277-3. Directional coupler No. 1 (DC-1) and its associated components form the power measuring circuit. They are calibrated as a unit at each of the N + 1 measurement frequencies, by connecting a calorimeter on the end of the line and manually tuning the tube to each frequency, as indicated by the components attached to directional coupler No. 2 (DC-2). It is permissible to use the calorimeter for all power measurements, and eliminate DC-1 and associated components, but this procedure is normally too slow for production testing.

The tube is oscillated at each of the N + 1 frequencies in turn, under the conditions specified on the TSS, and the CW power output and tuning voltage are measured at each point (other required electrode voltages and currents may be integrated with these measurements, but do not form part of this method). The differences of tuning voltage give the values of Po, for each segment. The difference of the first and last voltages give V. From these measurements, calculate ATS, STS, and P/TSP in accordance with the definitions given in 3.1. ATS shall not be less than the specified value. P/TSP shall not be less than the specified value, in each segment individually.

The measurements are illustrated on figure 4277-4. FIGURE 4277-4. Graph-tuning volts versus power output. 3.4 Dynamic presentation. A dynamic presentation can be obtained by inserting a wavemeter or tunable bandpass filter in the No. 1 directional coupler circuit, sweeping the tube with a linear (sawtooth) tuning voltage, and displaying the detected output on an oscilloscope.

Since the attenuation and bandwidth of a tunable filter are not generally constant across a wide tuning range, the system shall be calibrated by the static measurements described under 3.2; if the tube output is adjusted at each frequency segment so that the P/TSP is just equal to the specified minimum, and the corresponding oscilloscope deflection recorded under the dynamic conditions, a curve representing minimum acceptable response at each frequency is obtained which allows for the varying filter response and detector sensitivity. Note that the oscilloscope horizontal sweep is tied to the sweep of the tunable filter, not to the modulating voltage.

The frequency of the latter shall be much higher than the sweep frequency of the filter (which may be a manual sweep). In place of the tunable filter, a heterodyne system with a separate swept oscillator and fixed (IF) filter may be used. In this case the sweep frequency of the swept oscillator must be either much higher or much lower than the sweep frequency of the TUT, and the oscilloscope is locked to the slower one. The method of calibration is by reference to the static measurements as before. METHOD 4277A 4277-4 25 March 1970