Downloaded from https://www.everyspec.com MIL-STD-1311D 5. Phase measurements. 5.1 Phase shift. The purpose of this measurement is to determine the phase shift of the rf signal introduced by the insertion of the amplifier in the circuit. 5.1.1 Procedure. With the amplifier out of the circuit and the mainline of the directional couplers joined together by a section of transmission line of the same electrical length as the amplifier, the phase shift versus frequency is recorded. The phase can be balanced to zero at some convenient frequency by the phase shifter in order to simplify the computations.
With the amplifier inserted in the circuit and operating under its specified conditions, the phase shift versus frequency is again recorded with the phase shifter remaining at its previously calibrated position. Measurements shall be taken at each specified frequency. The phase shift of the amplifier is the difference between the two measurements at corresponding frequencies. 5.2 Phase linearity. The purpose of this measurement is to determine the linearity of the amplifier phase shift as a function of the rf frequency. 5.2.1 Procedure. With the amplifier inserted in the circuit and operating under its specified conditions, the phase shift is measured over the specified frequency range.
The frequency band shall be swept with a well leveled or programmed drive signal or enough measurements are taken at different frequencies to obtain a curve of the phase shift versus frequency. Phase linearity is the deviation in degrees of this curve from a straight line or specified curve, in a specified frequency interval giving minimum degradation after subtracting residual phase error introduced by the phase bridge components. 5.3 Phase sensitivity. The purpose of this measurement is to determine the sensitivity of phase shift with respect to amplifier applied voltage, current, and applied rf drive power, with the frequency held constant. 5.3.1 Procedure.
Measure the change in phase as the specified parameter is varied over the required range of values. All other operating conditions are to remain constant during this measurement. The change of phase is expressed in terms of degrees per units of the parameter varied (usually a 1.0 percent variation). 5.4 Phase stability. The purpose of this measurement is to determine the dependency of phase shift upon the passage of time. 5.4.1 Procedure. Phase measurements are taken at specific intervals while the amplifier is operating for the required number of hours. The slope of the phase shift versus time or the total phase shift over a certain time interval can be computed. 6. Precautions. a.
Variable attenuator shall be carefully selected to insure a linear phase response. b. Directivity of directional couplers shall be sufficient to make insignificant any error in phase due to input reflections or frequency changes. c. Mismatches at connection points shall be minimized. It may be advantageous to use lossy cable to minimize phase errors caused by multiple reflections. d. It may be necessary to use harmonic rejection filters. These filters shall have a good match and identical phase characteristics. METHOD 4278A 4278-3 25 March 1970