Downloaded from https://www.everyspec.com MIL-STD-1311D 4. Test circuit. Using the basic circuit given in figure 4278-1, the required phase tests shall be measured using either method A or B as appropriate. 4.1 Method A. 4.1.1 The phase comparator configuration on figure 4278-2 is inserted in 4278-1 as indicated by numbers 1, 2, and 3. It consists of a standing-wave indicator fed from both ends and a probe, terminated in a voltage indicator. The phase shifter is used to compensate for any existing phase shift which is not attributable to the amplifier under test. The incident power sampled by the directional couplers is applied to the two ends of the standing-wave detector.
For maximum measurement accuracy, the sampled powers arriving at the voltage indicator should be of nearly equal magnitude, and is achieved by using the variable attenuator. FIGURE 4278-2. Phase comparator configuration (method A). 4.1.2 Procedure. A reference position of the travel probe is established by adjusting the position of the probe for a minimum reading of the voltage indicator. The shift of the probe position in electrical degrees from the reference position to a position where the voltage indicator again shows a minimum is measured as a function of the change in operating conditions under consideration, for example: electrode potentials, electron current, or input rf drive.
The phase shift of the output signal in electrical degrees is twice the shift of the probe positions. 4.2 Method B. 4.2.1 An alternative method of measuring the phase shift of the output signal is shown on figure 4278-3 inserted in 4278-1 as indicated by numbers 1, 2, and 3. With this technique, the output signal sampled by the directional coupler goes to the probe of the standing-wave detector, and the voltage indicator is connected to one end of the standing-wave detector. In all other respects, the measuring setup is identical with figure 4278-2.
The measurement procedure is as before except that the phase shift of the output signal in electrical degrees will be equal to the shift of the probe position. FIGURE 4278-3. Phase shift measuring circuit (method B). METHOD 4278A 4278-2 25 March 1970