Downloaded from https://www.everyspec.com MIL-STD-1311D ELECTRONIC TUNING RANGE 1. Purpose. The purpose of this test is to measure electronic tuning range. 2. Definitions. a. Electronic tuning range is defined as the frequency range over which the TUT can be varied by adjusting specified electrical parameters after all other parameters have been optimized and then held constant. Simultaneously, the power output of the TUT shall not fall below the value specified on the TSS. b.
Multiresonator-oscillator electronic tuning range is defined as the frequency difference between the two points where the power first falls to the specified level as the controlling voltage is varied (usually dynamically) about the specified operating point. (In general, the maximum power point will not occur at mode center nor will the two peaks have equal amplitudes. Unless otherwise specified on the TSS, if external adjustment of resonator tuning(s) and feedback are inherent in the design, the operating voltage, resonator tuning(s), and feedback shall be mutually adjusted to produce a symmetrical continuous mode). 3. Equipment.
Use the circuitry of method 4250 and appropriate frequency measuring equipment. 4. Procedure. Measure and record frequency and output power versus the adjustable parameter(s). The test may be made on a static (point by point) or dynamic (swept) basis. If not specified, the test method is optional. The load and coupling shall be specified. Requirements or limits for tuning voltage, mode asymmetries and discontinuities, and hysteresis shall be specified. 5. Precautions. In many tube types, particularly those with multiple resonators, thermal tuning effects can cause wide variations in the data obtained, so that dynamic (swept) techniques are more useful than static test methods.
The sweep frequency should be chosen high enough to avoid these thermal tuning effects, but not so high as to cause high frequency instrumentation problems. METHOD 4280A METHOD 4280A 4280-1 25 March 1970