Downloaded from https://www.everyspec.com MIL-STD-1311D 5. Precautions. 5.1 Method A. The insertion loss of the tunable filter need not be considered, since it affects both signals equally, but any attenuator in one arm only must be taken into account. 5.2 Method B. The bandwidth and insertion loss of the tunable filter are likely to vary across the tuning range, and both should therefore be calibrated at each measurement frequency. 5.3 High- and low-pass filters may be necessary to remove out-of-band noise. 5.4 The output of the IF amplifier, displayed on an oscilloscope shall be observed and discrete noise components shall be noted. FIGURE 4282-1.