Downloaded from https://www.everyspec.com MIL-STD-1311D SERRODYNE OPERATION METHOD 4284 (Microwave amplifier tubes) 1. Purpose. The purpose of this method is to measure the spectral purity of a tube operated in the serrodyne mode. 2. Definition. Serrodyne operation is the method of frequency conversion by application of a sawtooth voltage to a transit-time device; e.g., a sawtooth helix voltage applied to a traveling-wave tube. 3. Test circuit. FIGURE 4284-1. Test circuit for serrodyne operation. 4. Procedure. An input signal and sawtooth wave, as specified by the TSS are applied. Power meter No. 1 is used to monitor the desired output P o1 .

The level of P o1 is to be set to the value specified by the TSS with bandpass filter No. 1 set to the desired frequency. The amount of frequency translation is equal to the difference between the input frequency F i and the output frequency F o at which the power P o1 is measured. For reference, F = (F i - F o ). The gain of the serrodyne device is measured between points A and B using method 4253, with P o1 set to the specified level. The gain shall be within the limits specified on the TSS but corrected for the loss of 3 dB through the directional coupler. Under the same conditions, bandpass filter No.

2 is set to F o ± ∆ F, F o ± 2 F (and as specified on the TSS) and power measurements taken at each of these frequencies. The maximum of these shall be less than the limit specified on the TSS as "suppressed power, P s ". The amount of amplitude modulation (AM) introduced by the serrodyne operation at F o shall be measured using method 4262, and shall be less than the limit specified on the TSS. METHOD 4284 4284-1 19 April 1968