Department of Defense MIL-STD-1311D — MIL-STD-1311D Test Methods for Electron Tubes — DoD Standard Manual PDF

Downloaded from https://www.everyspec.com MIL-STD-1311D HEATER OR FILAMENT CURRENT, NONOPERATING 1. Purpose. The purpose of this method is to specify the procedures for measuring heater or filament current. 2. Procedure. When the voltage specified on the TSS is applied to the heater or filament, the stabilized value of current shall be within the limit(s) specified. During this test no other elements shall be conducting. 3. Precautions. a. Apply the heater voltage in such a manner that the maximum surge current, if specified on the TSS, is not exceeded. b. If a warm-up time is specified, at least this amount of time shall be allowed for the heater current to stabilize. c.

Voltage and current measurements shall be corrected for incidental voltage drops and shunt currents due to the meters, in accordance with standard practice. d. When heaters or filaments are operated with low-capacitance (high-leakage reactance) transformers, or other non- sinusoidal sources, all measurements shall be made using instruments which will indicate true rms values including the harmonic power. e. Magnetic shielding between meters, or sufficient distance between magnetic fields or magnetic materials, is required so that accuracy of the meter readings is not affected. METHOD 4289 METHOD 4289 4289-1 19 April 1968