Department of Defense MIL-STD-1311D — MIL-STD-1311D Test Methods for Electron Tubes — DoD Standard Manual PDF

Downloaded from https://www.everyspec.com MIL-STD-1311D FREQUENCY CHANGE (WARMUP) 1. Purpose. The purpose of this test is to measure the short-term frequency variation which occurs when an oscillator is switched on. This method is not to be used for long-term frequency changes due to erosion or similar irreversible effects, nor the frequency changes due to changes in ambient conditions (see method 1023). 2. Frequency change. Initially the tube shall be under normal ambient conditions, with no voltages applied, and shall be connected to the specified load, with frequency-measuring equipment of adequate sensitivity to measure the small changes involved.

Heater power shall be applied for the specified time, followed by operating voltages in correct sequence. Time shall be measured from the moment (t o ) when these voltages are all fully applied. The frequency shall be measured at times t 1 and t 2 specified on the TSS; the absolute value of frequency difference F 1 shall be METHOD 4302A within the limit(s) specified on the TSS; if longer term thermal transients are also expected, a third time t 3 and frequency change F 2 may be specified. If no values are specified for times t 1, t 2 , and t 3 , the following shall be used: t 1 = 1 minute t 3 = 15 minutes t 2 = 3 minutes FIGURE 4302-1. Frequency change. 3. Drift rate.

When the drift rate is significant to the application, the TSS will specify a maximum slope (MHz/minute) and a time t b ; the slope may be measured as the difference of the frequencies measured at times t a , t c , bracketing t b , and differing by a small fraction of t b . The absolute value of the slope shall be within the limit(s) specified. METHOD 4302A 4302-1 25 March 1970