Downloaded from https://www.everyspec.com MIL-STD-1311D WARMUP TIME 1. Purpose. To describe techniques for the measurement of various warm-up times. 2. Equipment. Timing device, voltmeters, ammeters, power meters, frequency meters, and other equipment normally associated with testing a microwave tube. 3. Definition. Warm-up time is the time required for an observed characteristic to reach a specified value, or a specified percentage of the normal stabilized value, after the application of operating voltage(s). Typically these characteristics may be heater current, cathode current, output power, and frequency. 4. Measurements.

These measurements are normally made on a tube which has stabilized at room temperature in a nonoperating condition. The application of the heater voltage is normally the reference point for all time measurements. METHOD 4303 a. Heater warm-up time. The time interval (t 0 to t 1 ) between the application of heater voltage at time (t 0 ) and the time (t 1 ) when the heater current has decreased to within a specified percentage (usually 10 percent) of its normal stabilized value. In some cases a particular value of heater current is specified, so that in these cases the time (t 1 ) is read when the heater current has decreased to this value, after the initial heater surge. b.

Cathode warm-up time. The time interval (t 0 to t 2 ) between the application of the heater and anode voltage at time (t 0 ) and the time (t 2 ) when the cathode current at a particular anode voltage has increased to within a specified percentage (usually 90 percent) of its normal stabilized value. In some cases a particular minimum value of cathode current is specified, so that in these cases, the time (t 2 ) is read when the cathode current has reached this value. Precaution. It is normal to specify a minimum cathode preheating time (t 3 ) before the application of the anode voltage.

In these cases, the heater voltage is applied for the specified time interval before the anode voltage is applied, with the application of heater voltage as the time reference. c. Output power warm-up time. The time interval between the application of heater voltage (t 0 ) or anode voltage (t 3 ) and the time (t 4 ) when the rf output power has reached either a particular minimum, or a specified percentage (usually 90 to 95 percent) of its final stabilized value. Heater voltage and anode voltage may be applied simultaneously if cathode preheating is not required. Output power warm-up time shall be designated as either (t 0 to t 4 ) or (t 3 to t 4 ) as defined in the TSS. d.

Frequency warm-up time. See method 4302. METHOD 4303 4303-1 19 April 1968