Downloaded from https://www.everyspec.com MIL-STD-1311D PULSE CHARACTERISTICS METHOD 4304 (Microwave tubes) 1. Purpose. To define the characteristics of pulses; voltage, current, or microwave output, in a self-consistent fashion. 2. Equipment. An oscilloscope with a linear sweep and resolution better than 5 percent of tp having time jitter in a sweep circuit less than 5 percent of tp. If a crystal is used on measurement of an rf pulse, it shall be calibrated at the operating level. 3. Definitions.

Pulse definitions described on figure 4304-1 or figure 4304-2, in conjunction with table 4304-I, are self consistent in that pulse length, duty or power measurements made in accordance with them will have reasonable correlation among any two or three parameters. TABLE 4304-I. Levels A, B, and C as percentage of pulse amplitude (see figure 4304-1). METHOD 4304 4304-1 19 April 1968 Quantity: Power Voltage Current Nature of tube Value: A B C Space charge control tubes: 10 50 90 Value: A B C A B C A B C 33 70 95 33 70 95 Beam tubes (I = KV3/2 ): 10 50 90 10 70 90 10 70 90 Crossed field (M-type): 10 50 90 See figure 4304-2 10 50 90