Downloaded from https://www.everyspec.com MIL-STD-1311D PULSE VOLTAGE METHOD 4306A (Microwave tubes) 1. Purpose. The measurement of pulse voltages, exclusive of spikes, under a variety of conditions. 2. Equipment. A peak reading voltmeter is required, as indicated on the figures referenced to each method, including despiking circuitry. 3. If an oscilloscopic method is to be used, the oscilloscope should have Z axis capability so that measurement accuracy is not limited by the resolution of beam size relative to image size. 4. General. Errors in the measurement of peak voltage can arise from a number of factors including: a.

In the peak diode method, a high dynamic impedance of the diode may prevent full charging of the capacitors before the end of the pulse. b. Corona from capacitors or resistors which renders the low-level calibration inadequate and variable. c. Stray inductance and capacitance effects. 4.1 Careful design of the circuits can minimize these errors. Diodes should be selected to provide a minimum of shunt capacitive loading on the system whose pulse voltage is to be measured while at the same time offering an equivalent series impedance such that its product with C (figure 4306A-1) in the circuit is less than 25 percent of the length of the voltage pulse to be measured.

In some cases, it may be necessary to add series/resistance to low-impedance diodes so that this time constant acts as a despiker. 4.2 Similarly, corona and leakage can be controlled by careful electrode design or immersion of the system in oil, each of which adds to C (see figure 4306-1). 4.3 The impedance of the tube mount or its connection lead-ins may distort pulse shape of very fast pulses unless suitable distributive line techniques are used. 5. Method I (peak diode voltmeter). a. The following method is limited to applications at pulse voltages less than 35 kilovolts by diode and corona problems.

Within the range 0 to 35 kv, the accuracy may be improved if the components V, C, R, T, and shunt, if used, are enclosed in a dust free, temperature regulated compartment. Diode losses may be affected by filament voltage variations. The proper filament voltage will be that value from which a ± 10 percent change will not affect the meter reading. V = Suitable diode C = Energy storage capacitor, 40 kv rating M = Microammeter (suitable range) NOTE: The product tCR 1 shall exceed 6.0 T = Filament transformer, 20 pF (max) capacitance R 1 = Noninductive resistor t = Inter-pulse period FIGURE 4306-1. Voltmeter circuit. METHOD 4306A 4306-1 25 March 1970