Downloaded from https://www.everyspec.com MIL-STD-1311D b. The standard voltmeter circuit shall be used with a resistive divider as shown on figure 4306-2 calibrated on the test modulator with a laboratory standard capacity divider. The resistors, Ra and Rb, are not critical and should be chosen to operate the standard circuit within its voltage rating, but because of stray capacitance and inductance, the applicable range of pulse lengths may be limited. 6. Method II (cathode-ray display). 6.1 Resistive divider method.

The following method may be used at all voltages above or below 35 kv, for pulse lengths between 0.5 and 10 microseconds and duty cycles on the order of 0.001; additional capacitive compensation may be required if the rise time is less than 0.25 µ s. This method is applicable if no diode is available or if errors from spike or pickup of cathode lead radiation are suspected. It is not suitable for testing low-power pulse tubes (for example, beacon magnetrons), because the additional loading on the modulators is then excessive. The method uses a resistive voltage divider to reduce the pulse voltage by a factor of the order of 1,000. The divided pulse is measured on a calibrated oscilloscope.

The circuit is shown on figure 4306-3 and the physical layout of the resistive divider on figure 4306-4. a. The total resistance shall be kept low enough to swamp capacitive errors; the value depends on the environment, and on the division ratio desired, but in general should be not higher than 40,000 ohms. A range of 10,000 to 25,000 ohms is preferred. b. The wattage rating of the resistors shall be not less than 2.5 times the expected average dissipation, which is: ce resis divider cycle duty x voltage peak tan ) ( 2 This dissipation is higher than in conventional dividers, but is still not a significant load on a high-power modulator. For example:

70 kv, with 0.001 duty cycle, ten 90 watt 2,500-ohm resistors may be used. c. To minimize inductive effects, composition film (VHF) resistors (MIL-PRF-22684), or equivalent, must be used. Noninductive wire-wound resistors are not satisfactory in this application. The resistors should be arranged in a planar zig-zag array on an insulting baseboard. The clips at the high-voltage end may require rounding to prevent corona. At very high voltages the whole assembly may be immersed in an oil bath. d. To minimize the effect of voltage coefficient of resistance, the same type of resistor should be used throughout. e. Effects of the connecting cable are eliminated by matching it at both ends.

The effective low-end resistance is then half the cable characteristic impedance. Preferred values are 50-ohm cable, terminated in 50 ohms at each end to give 25 ohms resistance. Overall divider resistances of 10,000 to 25,000 ohms then give ratios in the range 400 to 1,000 to yield convenient oscilloscope inputs. f. The exact ratio is determined by measuring the high and low resistances with a precision dc bridge. Owing to the use of thin film resistors, the ratio remains constant to very high frequencies. g. The pulse height on the oscilloscope may be measured by conventional use of the y-deflection calibration.

The method of use, and of calibration against a standard voltmeter or a standard voltage source, will depend on the type of oscilloscope used. A square wave voltage calibrator may be used provided it can in turn be referred to a standard instrument. METHOD 4306A 4306-2 25 March 1970