Downloaded from https://www.everyspec.com MIL-STD-1311D FREQUENCY PULLING FIGURE 1. Purpose. To determine the susceptibility of a tube to change its oscillating frequency as a result of changes in load. In actual practice a change in reflection coefficient may result from the motion of an antenna system with near field variations, or from the motion of the microwave plumbing elements themselves. 2. Definition. The pulling factor is the maximum oscillating frequency excursion obtained when a tube is exposed to its specified load VSWR being dynamically varied through all phase angles.
The rate of this variation shall be rapid enough to minimize thermal effects, and gradual enough to permit observation of instability, if present, at each phase position. 3. Equipment. See figures 4310-1 and 4310-2. 4. Test circuits. Either method A or B shall be performed. The choice will be the manufacturer’s option. 4.1 Method A. METHOD 4310A FIGURE 4310-1. Pulling factor test circuit method A. 4.1.1 Procedure. The standing-wave introducer is adjusted such that at any phase position the tube is exposed to a minimum VSWR of 1.5:1. The total frequency excursion is measured by the frequency indicator when the standing-wave introducer traverses all phase positions as previously defined.
4.2 Method B. FIGURE 4310-2. Pulling factor test circuit method B. METHOD 4310A 4310-1 25 March 1970