Downloaded from https://www.everyspec.com MIL-STD-1311D 4.2.1 Procedure. The fixed mismatch and phase shifter are chosen such that in any phase position the tube is exposed to a minimum VSWR of 1.5:1. The total frequency excursion is measured by the frequency indicator when the phase shifter traverses all phase positions as previously defined. 5. Precautions. 5.1 The elements producing the 1.5:1 VSWR shall be close to the tube in order to eliminate any "long-line effects." 5.2 When the tube is retested at other than the manufacturing location, the tube shall not be exposed to a VSWR greater than 1.5:1 at any phase position.

5.3 The specified tube operating conditions are not readjusted during the pulling factor measurement. 5.4 The frequency indicator shall be capable of measuring instantaneous frequency values with the required accuracy. Commonly accepted frequency indicators are the spectrum analyzer, the electronic frequency counter, and the cavity wavemeter. 5.5 In calibration of the standing-wave introducer it is desirable that harmonics of the signal be of negligible proportion, and that a significant number of phase positions of the introducer be measured and plotted to show that the VSWR/phase plot is circular. A non-circular plot is an indication of unwanted resonances.

METHOD 4310A 4310-2 25 March 1970