Downloaded from https://www.everyspec.com MIL-STD-1311D PULSE STABILITY 1. Purpose. To evaluate the pulse output power stability of microwave tubes. 2. General. Microwave tubes are generally quite stable so that it is generally expedient to measure instead the occasional instabilities which arise because of internal or external effects. Pulses may be deficient in power output when an arc occurs in the cathode circuit or in the microwave resonant circuits when the tube operates wholly or in part in the wrong mode.

Since stability is often a function of time elapsed since turn-on (cathode activity or gas clean-up) it is expected only one of the following tests will be specified on any tube type. Stability of a microwave tube shall be expressed in terms of the percent of all pulses which are missing or deficient. A missing or deficient pulse is one whose total energy content within a specified bandwidth is less than the minimum value specified. The minimum value is 70 percent of the average total energy content of each of a series of complete pulses, or may be expressed as 1.5 dB down from that energy level. 3. Equipment.

In addition to the equipment required for the power levels test (method 4250), the following additional equipment is required: a. Means of introducing a standing wave in the output system and varying its phase through all possible values while at the same time maintaining VSWR in excess of the specified value. b. Power divider (directional coupler) to obtain a sample of RF output. c. A frequency selective crystal detector system of specified RF bandpass. d. Reference input pulse from the modulator which is time coincident with the pulse applied to the tube. e. Missing pulse detector as shown on figure 4315-1 capable of recording random missing pulses or clusters of missing pulses. 4.

Procedure. The tube shall be operated into the stated load whose phase is adjusted to that which produces the greatest number of deficient pulses. The level of the rf power applied to the input of the bandpass filter and detector is adjusted so that all pulses are just counted. The level is then increased by the specified amount and the number of missing pulses are counted over a specified period. 4.1 Stability. The missing pulses observed according to the above procedure over the specified time base interval expressed in percent of the total pulses applied during the interval shall not exceed the value specified. 4.2 Starting stability.

This test shall be performed as the first test following the holding period. Since the time required to set up the measuring conditions may vary, the maximum allowed time for setting up shall not be included in the measuring period. Stability as in 4.1 shall be measured in the first time base interval which begins no later than the end of the allowed setup time. 4.3 Snap-on stability. This test shall be the first test following a specified period of inactivity, using the specified load. Prior to starting the test period it is generally found convenient to adjust input to the tube and output VSWR approximately to the specified values using another tube.

Then the "snap-on" tube is inserted in the socket and heater power is applied. After the specified warm- up period full pulse voltage is suddenly applied. Missing pulses, observed as in 4.1, shall be measured with the time base interval starting at the instant of application of the first pulse. 4.4 Runup stability. This test shall be performed as the first test following the holding period. Upon completion of the heater warm-up time, apply eb = 0 and runup at the specified rate to Po test conditions. Stability as in 4.1 shall be measured using a time base which begins immediately after reaching Po test conditions. METHOD 4315A METHOD 4315A 4315-1 25 March 1970