Downloaded from https://www.everyspec.com MIL-STD-1311D IGNITOR VOLTAGE DROP 1. Purpose. The purpose of this test is to determine the voltage drop of the ignitor under specified operating conditions. 2. Equipment. The test circuit shall consist of a variable voltage supply, a series resistor, a microammeter, and a high- impedance voltmeter. (This test may be made in conjunction with the ignitor ignition time test, method 4401, using the circuit shown on figure 4401-1.) 3. Procedure. With the ignitor current adjusted to the value specified, the voltage drop across the tube shall be measured. METHOD 4406 METHOD 4406 4406-1 19 April 1968