Downloaded from https://www.everyspec.com MIL-STD-1311D (OBSOLESCENT) METHOD 4411 IGNITOR OSCILLATION (TR tubes) The tube shall be placed in the circuit as shown on figure 4411-1, or equivalent circuit. With the supply voltage adjusted to 800 V dc, the ignitor current shall be set by means of the variable resistor in series with the ignitor electrode. The minimum current that will prevent low-frequency relaxation oscillations shall be within the limit(s) specified on the TSS. The high-frequency oscillations cause no difficulties. Relaxation oscillations are indicated on the oscilloscope trace when the current drops below the level of the high-frequency relaxation oscillations. FIGURE 4411-1.

Ignitor oscillation circuit. METHOD 4411 4411-1 19 April 1968