Department of Defense MIL-STD-1311D — MIL-STD-1311D Test Methods for Electron Tubes — DoD Standard Manual PDF

Downloaded from https://www.everyspec.com MIL-STD-1311D (OBSOLESCENT) METHOD 4431 TUNING (TR TUBES) 1. Purpose. This test applies to fixed tuned tubes used in conjunction with an external cavity to function as a TR tube. Its purpose is to determine whether the fixed tuned tube meets the specified frequency limits when tested in a specified cavity. The resonant frequency of the combination is largely dependent upon the cavity internal dimensions so these shall be specified in detail on the TSS. 2. Equipment. The equipment layout as shown on figure 4431-1 may be used for this test. More than one cavity (different internal dimensions) may be specified to check the tube at different frequencies.

FIGURE 4431-1. Equipment layout for tuning (TR tubes) measurements. 3. Procedure. The tube shall be mounted in the specified external cavity and placed between a matched generator and detector. The signal generator frequency shall be varied to obtain the resonant frequency of the tube and cavity as evidenced by a pronounced peak at the output indicator. The value of this resonant frequency shall be within the limit(s) specified. METHOD 4431 4431-1 19 April 1968