Downloaded from https://www.everyspec.com MIL-STD-1311D LOW-LEVEL VSWR METHOD 4473 (Gas-switching tubes) 1. Purpose. To measure the voltage standing-wave ratio as a function of frequency for the TUT when not ionized. 2. Equipment. The tube shall be mounted in a low-level transmission circuit between a matched generator and matched termination. Figure 4473-1 shows the basic circuit for single tubes, and figure 4473-2 shows the circuit for dual tubes. FIGURE 4473-1. Equipment layout for single tube low-level VSWR measurement. FIGURE 4473-2. Equipment layout for dual tube low-level VSWR measurement. METHOD 4473 4473-1 19 April 1968