Department of Defense MIL-STD-1311D — MIL-STD-1311D Test Methods for Electron Tubes — DoD Standard Manual PDF

Downloaded from https://www.everyspec.com MIL-STD-1311D (OBSOLESCENT) METHOD 4476 INTRINSIC P (TR tubes) 1. Intrinsic P (P'). The tube shall be mounted in the specific cavity and placed in a circuit between a matched generator and detector. The resonant cavity and its associated tube shall be excited from the signal generator through a matched attenuator and standing-wave detector, and the input power adjusted to a level that is insufficient to fire the tube. The frequency of the signal generator shall be tuned to the resonant wavelength of the cavity as indicated by a pronounced peak in the power observed in the output circuit.

The output and input coupling mechanisms (either loops or rises) shall be adjusted until the input to the cavity is matched to the transmission line as measured by the standing-wave detector, and until the low-level transmission T is between 0.1 and 0.01. The transmission T is defined as the ratio of the power transmitted through the cavity at resonance, to the power available at the input to the cavity when measured by removing the cavity and connecting the power-measuring device to the input transmission line. With each change in the coupling, the signal generator shall be retuned to resonance.

After final adjustment, the resonant wavelength λ o and low-level transmission T shall be measured and recorded. The frequency of the signal generator shall then be decreased until the power transmitted through the cavity has dropped to one-half its value at resonance. The wavelength corresponding to this point shall be measured and recorded as λ 1. The frequency shall then be increased above resonance to the half-power point and this wavelength measured and recorded as λ 2. The signal generator shall be retuned to resonance and the input power level increased to the amount stated on the specification sheet, which should be sufficient to fire the tube gap.

No change should be made in the adjustments of the coupling mechanisms. The power in watts measured in the output circuit under these conditions shall be recorded as Pr. The value of P'o shall be computed from the following equation: amperes volt T o o P = ) 2 1 ( Pr 2 ' λ λ λ It should be noted that λ o, λ 1, λ 2, and T are all measured at low levels with the tube unfired, and that Pr is the only quantity measured when the tube is fired. When the required input power is specified in terms of the power into the gas discharge, this is computed from the following equation:

= o o P o o P P Pg λ λ λ λ λ λ 2 ) 2 1 ( ' 2 ) 2 1 ( ' 2 / 1 Where Pg is the power in the gas discharge, P is the available power at the input to the cavity, and the other symbols are already defined. In the event that it is impossible or inconvenient to adjust the coupling mechanisms to the cavity to the matched input conditions, the intrinsic P can be expressed as: = g T o o P 1 1 ) 2 1 ( Pr 4 ' λ λ λ + Where: g = Normalized input admittance to the cavity. Pg = + ) 1( ) 2 1 ( ' ) 1( 1 ) 2 1 ( ' 2 / 1 g g o o P g o o P P λ λ λ λ λ λ + METHOD 4476 4476-1 19 April 1968