Department of Defense MIL-STD-1311D — MIL-STD-1311D Test Methods for Electron Tubes — DoD Standard Manual PDF

Downloaded from https://www.everyspec.com MIL-STD-1311D r 1 depending upon whether g is greater or less than unity. Defining the VSWR before the tube as r, where r > 1, g is equal to r or The ambiguity can be resolved as follows: The position of a minimum in the standing wave-pattern is measured along the standing wave-detector from an arbitrary origin. If g resonance to the position of the minimum at frequencies far off resonance. If g > 1, the position of the minimum will be the same at resonance as for frequencies far off resonance. 2. Intrinsic P (relative).

The tube shall be tested on a relative basis, under the conditions specified in 1, by comparing the reading of the output indicator when the tube gap is fired with tubes having known intrinsic P values within the specified limits. The readings of the output indicator are assumed to be proportional to the value of intrinsic P. The cavity temperature shall be 47 ° C ± 3 ° C and the tube temperature shall be 45 ° C or higher, when inserted in the cavity. METHOD 4476 4476-2 19 April 1968