Downloaded from https://www.everyspec.com MIL-STD-1311D 3. Procedure. With the tube installed in the appropriate circuit, the line power is set at the specified level as observed on power detector No. 1. The arc loss, L a , shall be taken as the dB change in power at the termination, when the tube is replaced by a metallic short circuit. 4. Equipment. The 3 dB hybrid couplers used shall have a maximum terminated VSWR of 1.10 over the specified frequency range. Each coupler shall split the power evenly to within 0.25 dB and shall have a minimum isolation of 25 dB. 5. Formula. Although the loss may be read directly from the power meter, it may be also computed from: