Downloaded from https://www.everyspec.com MIL-STD-1311D DUPLEXER LOSS METHOD 4489 (Dual gas-switching tubes) 1. Purpose. The purpose of this test is to determine the loss of power incurred in a transmission line due to the insertion of the tube in the transmission line. 2. Equipment. The following basic equipment layout, or its equivalent using an electronically swept generator, may be used for this test. FIGURE 4489-1. Equipment layout for duplexer loss measurements. 3. Procedure. 3.1 Non-isolated transmitter. Using a no-loss simulated tube, the transmitted power is measured in the receiver port.
With the TUT in the circuit, the adjustable short is adjusted for minimum power (maximum duplexer loss) at the reference frequencies. The duplexer loss shall be within the limits specified as read on the power meter or viewed on the oscilloscope at the receiver port. 3.2 Isolated transmitter. Using a matched load on the transmitter arm, the difference in power loss measurements of the simulated no-loss tube and the TUT shall be within the limits specified. 4. Equipment. The 3 dB hybrid couplers used shall have a maximum terminated VSWR of 1.10 over the specified frequency range; split the power evenly to within 0.25 dB; and shall have a minimum isolation of 25 dB. 5. Formula.
Although the loss may be read directly from a power meter or calibrated oscilloscope, the duplexer loss may be computed as follows: a d P P L log 10 = Where: r P a = Power at the antenna port. P r = Power at the receiver port. METHOD 4489 4489-1 19 April 1968